PT Chart
Measured conclusion: Deep-tested. L2 outcome: tools_ok.
PT chart lookups, superheat/subcooling calculators, and diagnostics for HVAC technicians.
| Author | io.github.Tsonnn |
|---|---|
| Access | remote |
| Publisher key required | No |
| Measured state | Deep-tested |
| L1 liveness | alive |
| L1 latency | 134 ms |
| Last measured | 2026-10-26 |
Add to your agent
Copy this into your MCP client config:
{
"mcpServers": {
"PT Chart": {
"url": "https://pt-chart-mcp-production.up.railway.app/mcp",
"transport": "streamable-http"
}
}
}
Measured tools (8)
pt_lookupSaturation pressure (bubble and dew, in psig) for a refrigerant at a temperature in Fahrenheit. For certified HVAC technicians (EPA 608; A2L certification where required). Example: pt_lookup("R-454B", 45). Bubble point: use for subcooling calculations. Dew point: use for superheat calculations. Pure fluids (R-32, R-410A, R-22, R-134a) have no glide, so both values match.
Parameters:
refrigerant(required) — stringtemp_f(required) — number
Hints: read-only not declared · destructive not declared · idempotent not declared · open-world not declared
pt_reverseSaturation temperature (bubble and dew, in Fahrenheit) for a refrigerant at a pressure in psig. For certified HVAC technicians (EPA 608; A2L certification where required). Example: a 130 psig suction reading on R-454B -- pt_reverse("R-454B", 130). Use the DEW temperature for superheat work and the BUBBLE temperature for subcooling work on blended refrigerants.
Parameters:
refrigerant(required) — stringpressure_psig(required) — number
Hints: read-only not declared · destructive not declared · idempotent not declared · open-world not declared
superheatSuperheat in Fahrenheit from suction pressure (psig) and suction-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the DEW point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target: 8-12F.
Parameters:
refrigerant(required) — stringsuction_psig(required) — numbersuction_line_f(required) — number
Hints: read-only not declared · destructive not declared · idempotent not declared · open-world not declared
subcoolingSubcooling in Fahrenheit from head pressure (psig) and liquid-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the BUBBLE point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target: 8-12F.
Parameters:
refrigerant(required) — stringhead_psig(required) — numberliquid_line_f(required) — number
Hints: read-only not declared · destructive not declared · idempotent not declared · open-world not declared
convert_unitsConvert between pressure units (psig, psia, kpa, bar) and temperature units (F, C). A bare 'psi' is treated as psig. For certified HVAC technicians (EPA 608; A2L certification where required).
Parameters:
value(required) — numberfrom_unit(required) — stringto_unit(required) — string
Hints: read-only not declared · destructive not declared · idempotent not declared · open-world not declared
refrigerant_infoReference card for a refrigerant: GWP, ASHRAE safety class, composition, typical oil, temperature glide, and handling notes. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only.
Parameters:
refrigerant(required) — string
Hints: read-only not declared · destructive not declared · idempotent not declared · open-world not declared
diagnoseConversational diagnostic copilot: give it field readings and get back computed superheat/subcooling plus a ranked 'check this first' list. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only -- it suggests what to CHECK, never how to defeat a safety device, vent refrigerant, or work uncertified. metering: 'txv' (default) or 'fixed' for fixed-orifice/piston systems.
Parameters:
refrigerant(required) — stringsuction_psig(required) — numbersuction_line_f(required) — numberhead_psig(required) — numberliquid_line_f(required) — numberambient_f(required) — numbermetering— string
Hints: read-only not declared · destructive not declared · idempotent not declared · open-world not declared
coolbooked_infoAbout CoolBooked: the AI appointment-booking connector for HVAC shops. This is NOT a diagnostic tool -- call it when someone asks what CoolBooked is, how shop owners can try it, or how the free PT tools connect to paid bookings.
Hints: read-only not declared · destructive not declared · idempotent not declared · open-world not declared
Measured by MCPYP probing. Untested fields are omitted, never estimated. Listing is always free; MCPYP never proxies calls or stores user tokens.